What we do We are involved in technology, Natural and Medical Sciences. We offer integrated, engineering and technical solutions, based on our experience in the research and development (R+D) field for companies, groups of researchers and scientists. We are specialized in the multidisciplinary design and development of custom-made systems, subsystems, products, accessories and/or parts for life sciences. We provide our clients with a full service in electronics, electromechanics, mechanics, optoelectronics, materials and/or firmware. Skills and Capabilities Design and development of systems (Optoelectronical, Electronical, Electromechanical, Mechanical, Firmware). Design, development and manufacture of hardware equipment. Research and Development Services (from the idea to the product). 3D mechanical design and simulation. 3D Printing capabilities. Electronics circuits design and simulation. Laser cutting capabilities. CNC machining capabilities. POS systems programming. ARM Cortex microcontrollers based systems. Microchip microcontrollers based systems. RTOS and Bare Metal MCU programming. ASM/C programming. TPC/IP communication over Ethernet or Wifi. IEEE 802.15.4 Zigbee. RFID Technologies. Lead acid and lithium battery powered systems. TFT and graphical displays. GPS/GPRS/GSM systems. Accelerometer based systems. Pressure sensors. PID based control loops. RS232/USART CAN protocol. USB/SD storage capacity. MP3 decoding for audio purposes. AC load controllers with errors detection. Valves for liquid control. Software versioning and revision control system (Git and SVN). Contact info@emsurbioing.com.ar
Serial Dilatator and Tubular Retractor for minimally invasive spinal surgery Design and production. Manufactured in Stainless Steel 316L. Neuronavigator – Image Guided Surgery (IGS) System – LUTi Image Guided Surgery System LUTi is a handy "GPS system" for surgeons View more at Youtube: LUTi Navigator IGS Stereotactic Neurosurgery Simulator oriented to Biopsies Research, development, and implementation of a stereotactic neurosurgery simulation system View more at Youtube: NeuroSIM Image Guided Surgery (IGS) Tools Design and production of mechanical accessories for surgical systems produced by Clarontech (Toronto – Canada- www.clarontech.com). Injector System Battery based electronic design and prototyping used for hyaluronic acid, micro-fat, nano-fat, and anesthesia injection through a mechanical system. 8 bits Microcontroller @32 MHz at 1.8v. Active filters for signal processing. Four layers PCB with 0402 components. RGB leds achieving 32 colors. PCB dimensions: 10 x 50 mm. IEC 60601-1 compliance. CE marking. 2.4 GHz ZigBee Transceptor Design and production. Microcontrolled transceptor module for wireless communication over 2.4GHz based on ZigBee IEEE 802.15.4 standard at 1 Mbs. 8 Bit microcontroller at 48MHz.Voltage 5v. Based on Texas Instruments design.C programming.Four layers PCB with 0402 footprints. Dimensions: 50 x 50 mm Streaming Audio player over internet Device with ETH capabilities, mass storage interface and audio interface for reproducing audio files with integrated MP3 decoding libraries. Core ARM Cortex-M4 32 Bits @168 MHz + 192KB RAM + 1 MB ROM. 4 Bits SDIO interface. FAT32 file system. PHY layer via RMII port. Ethernet port 10/100 Mbs.24 bits stereo DAC with I2S interface 2 layers PCB. Dimensions: 50 x 80 mm AC Load Controller with Errors Detection Design and production.12 channels driver device for AC loads with error detections orientated to Street lights control. 8 Bit microcontroller @32MHz. 12 channels. 220v @ 10A. No load detection. False shot detection. No shot detection. I2C communication. Dimensions: 220 x 150 mm Pneumatic Tourniquet System
Complete system design and production. 8 Bits Microcontroller @ 48MHz. Pneumatic system for cuff pressure management. Lead-Acid battery with dedicated charger module and Wall adapter. USB communication for configuring. PID (Proportional- Integral- Derivative) tailored control system. Graphical User Interface with keyboard and display. Two layers PCB with 0603 components. PCB dimensions: 100 x 120 mm. IEC 60601-1 compliance. Air Flow Incubator (Low Noise) Complete system design and production. 8 Bits Microcontroller @ 32MHz. PID digital temperature control system, specially designed for low vibrations and high thermal stability. Two layer PCB through hole. 8 bit microcontrolled. Graphical User Interface with keyboard and display. 220V 1A power. Perfusion chamber incubator Complete system design and production. 8 Bits Microcontroller @ 32MHz. PID digital temperature control system, specially designed for low electromagnetic radiation emission. Graphical User Interface with keyboard and display. Two layer PCB through hole. 8 bit microcontrolled. 220V 0,1A power. Electroporator Complete system design and production. 8 Bits Microcontroller @ 32MHz. Square wave electroporation system for experimental purposes in live and in vitro samples. Graphical User Interface with keyboard and display. Two layer PCB trhoghhole. 8 bit microcontrolled. 220V 0,1A power. https://www.ncbi.nlm.nih.gov/pmc/article s/PMC2655258/ Perfusion chambers and accessories Designs, develops and manufactures custom-made and/or standard parts, adapters and perfusion chambers. Available in different polymers ( Polymethylmethacrylate, polycarbonate, Polyoxymethylene, Nylon6, Polytetrafluoroethylene, etc.) and metals (Aluminium, Stainless Steel, etc.). System to validate parkinsonian rodents Angular position monitoring system, for experimental animals. Complete system design and production. 8 Bits Microcontroller @ 32MHz. Algorithm design and validation. Two layer PCB through hole. 8 bit microcontrolled. Intracranial pressure (ICP) monitoring Complete system design and prototyping (including catheter balloon). 8 Bits Microcontroller @ 32MHz. Graphical User Interface with keyboard and display. Two layer PCB through hole. 8 bit microcontrolled. 220V 0,1A power. https://www.youtube.com/watch?v=G-y0 BbXXHxQ